Initial Configuration
This section describes the procedures for the initial configuration of the device.
The device is supplied with software pre-installed. By default, the device has a default IP address that is most likely inaccessible from the customer's network.
Default IP Address
|
Parameter |
Value |
|---|---|
|
IP Address |
192.168.0.2 |
|
Subnet Mask |
255.255.255.0 |
|
Default Gateway |
0.0.0.0 |
Initial access to and configuration of the device can be done using any of the following device management interfaces:
| ■ | Web interface: |
| a. | Connect a computer directly to the GE_1 port. |
| b. | Configure the computer network to reside on the same subnet (e.g., 192.168.0.Y/24). |
| c. | Access the Web interface (https://192.168.0.2) for initial configuration. Refer to the Mediant 7000 User's Manual for more details on network configuration and other configuration using the Web interface. |
| ■ | CLI: |
| a. | Access the CLI using one of the following methods: |
| ◆ | Serial access: Run a terminal utility running on your computer and use a serial port through the USB port on the computer (see Using Serial Access to Device). |
| ◆ | SSH access: Use the default IP address (192.168.0.2) on port 22. |
| ◆ | Network through the BMC Web interface (see Using BMC Web Interface). |
| a. | See Reconfiguring Default IP Address to Match Network Settings to connect to the Web interface. |