Active Alarm Table Alarm

acActiveAlarmTableOverflow

Alarm

acActiveAlarmTableOverflow

OID

1.3.6.1.4.15003.9.10.1.21.2.0.12

Description

The alarm is sent when an active alarm cannot be entered into the Active Alarm table because the table is full.

Default Severity

Major

Source Varbind Text

System#0<n>/AlarmManager#0

Event Type

processingErrorAlarm

Probable Cause

resourceAtOrNearingCapacity (43)

Alarm Severity

Condition

Text

Corrective Action

Major

Too many alarms to fit in the active alarm table

"Active alarm table overflow"

Some alarm information may be lost but the ability of the device to perform its basic operations is not impacted.
A restart is the only way to completely clear a problem with the active alarm table.
Contact AudioCodes Support.

Remains 'Major' until restart. A 'Clear' trap is not sent.

After the alarm is sent

-

Note that the status remains 'Major' until restart as it denotes a possible loss of information until the next restart. If an alarm is sent when the table is full, it is possible that the alarm is active, but does not appear in the active alarm table.