HA System Configuration Mismatch Alarm
This alarm is applicable only to products supporting HA (Mediant 500, Mediant 800, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software).
acHASystemConfigMismatchAlarm
Alarm |
acHASystemConfigMismatchAlarm |
||||||||
---|---|---|---|---|---|---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.34 |
||||||||
Description |
The alarm is sent when the Active and Redundant devices in the High Availability (HA) system are not identical, causing instability. For example:
|
||||||||
Default Severity |
Major |
||||||||
Source Varbind Text |
System#0/Module#<m>, where m is the blade module’s slot number |
||||||||
Event Type |
processingErrorAlarm |
||||||||
Probable Cause |
configurationOrCustomizationError |
||||||||
Severity |
Condition |
Text |
Corrective Action |
||||||
Major |
License Keys of Active and Redundant units are different. |
"Configuration mismatch in the system: Active and Redundant modules have different feature keys." |
Update the License Keys of the Active and Redundant units. |
||||||
The Active unit was unable to pass on to the Redundant unit the License Key. |
"Configuration mismatch in the system: Fail to update the redundant with feature key." |
Replace the License Key of the Redundant unit because it may be invalid. |
|||||||
License key of the Redundant unit is invalid. |
"Configuration mismatch in the system: Feature key did not update in redundant module." |
Replace the License Key of the Redundant unit because it may be invalid. |
|||||||
Configuration of Active and Redundant devices are different due to offline parameters that require a restart for their settings to apply. |
"Offline configuration was changed, HA is not available until next system reboot." |
Restart the device. Note: For devices that support FIPS, this alarm reason is also sent if the FIPS mode differs between devices. To resolve the issue, enable FIPS mode on the device where it is currently disabled. |
|||||||
Cleared |
Successful License Key update |
"The feature key was successfully updated in the redundant module" |
- |