Configuring Internal Clock as Clock Source
You can configure the device to use its internal clock source. When the device has no line interfaces, the device should be configured in this mode.
|
➢
|
To configure internal clock as clock source: |
|
1.
|
Set the clock source to be from the device's internal oscillator. In the TDM Bus Settings page, set the 'TDM Bus Clock Source' parameter (TDMBusClockSource) to Internal. |
|
2.
|
(E1/T1 Trunks Only) Set the line to drive the clock on all trunks: In the Trunk Settings page, set the 'Clock Master' parameter (ClockMaster) to Generated (for all trunks).
|