Restoring Factory Defaults through CLI
You can restore the device to factory defaults through CLI.
|
➢
|
To restore factory defaults through CLI: |
|
a.
|
Connect the RS-232 serial port of the device to the communication port on your computer. For serial cabling, refer to the Hardware Installation Manual.
|
|
b.
|
Establish serial communication with the device using a serial communication program (such as HyperTerminalTM) with the following communication port settings:
|
|
2.
|
At the CLI prompt, type the username (default is "Admin" - case sensitive), and then press Enter:
|
# Username: Admin
|
3.
|
At the prompt, type the password (default is "Admin" - case sensitive), and then press Enter:
|
# Password: Admin
|
4.
|
At the prompt, type the following, and then press Enter:
|
# enable
|
5.
|
At the prompt, type the password again, and then press Enter:
|
# Password: Admin
|
6.
|
At the prompt, type one of the following commands, and then press Enter:
|
|
●
|
To restore all configuration to factory defaults: |
# write factory