General Parameters

The general debugging and diagnostic parameters are described in the table below.

General Debugging and Diagnostic Parameters

Parameter

Description

enablesecsyslog

[EnableSecSyslog]

Enables the reporting of security-related events for the data-router networking. When enabled, the data-router access list rules, configured using the access-list CLI command, which are set to "log", send Syslog messages whenever traffic matching the access list is encountered.

[0] = (Default) Disabled
[1] = Enabled

'Delay After Reset [sec]'

configure voip > sip-definition advanced-settings > delay-after-reset

[GWAppDelayTime]

Defines the time interval (in seconds) that the device's operation is delayed after a reset.

The valid range is 0 to 45. The default is 7 seconds.

Note: This feature helps overcome connection problems caused by some LAN routers or IP configuration parameters' modifications by a DHCP server.

configure system > hw > usb-power

[UsbPowerCtrl]

Shuts down the USB port(s), by disconnecting power to them.

[0] = Off - power disconnected and port shutdown.
[1] = (Default) On - power connected and port up.

[EnableAutoRAITransmitBER]

Enables the device to send a remote alarm indication (RAI) when the bit error rate (BER) is greater than 0.001.

[0] = Disable (default)
[1] = Enable