Working with DMS-100 Switches
                                            The DMS-100 switch requires the following NFAS Interface ID definitions:
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | InterfaceID #0 for the Primary trunk | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | InterfaceID #1 for the Backup trunk | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | InterfaceID #2 for a 24 B-channel T1 trunk | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ■ | InterfaceID #3 for a 24 B-channel T1 trunk, and so on for subsequent T1 trunks | 
                                            
                                            For example, if four T1 trunks on a device are configured as a single NFAS group with Primary and Backup T1 trunks that is used with a DMS-100 switch, the following parameters should be used:
NFASGroupNumber_0 = 1
NFASGroupNumber_1 = 1
NFASGroupNumber_2 = 1
NFASGroupNumber_3 = 1
DchConfig_0 = 0    ;Primary T1 trunk
DchConfig_1 = 1    ;Backup T1 trunk
DchConfig_2 = 2    ;B-Channel NFAS trunk
DchConfig_3 = 2    ;B-channel NFAS trunk
                                            If there is no NFAS Backup trunk, the following configuration should be used:
ISDNNFASInterfaceID_0 = 0
ISDNNFASInterfaceID_1 = 2
ISDNNFASInterfaceID_2 = 3
ISDNNFASInterfaceID_3 = 4
ISDNIBehavior = 512   ;The parameter should be added because of ;ISDNNFASInterfaceID coniguration above
NFASGroupNumber_0 = 1
NFASGroupNumber_1 = 1
NFASGroupNumber_2 = 1
NFASGroupNumber_3 = 1
DchConfig_0 = 0    ;Primary T1 trunk
DchConfig_1 = 2    ;B-Channel NFAS trunk
DchConfig_2 = 2    ;B-Channel NFAS trunk
DchConfig_3 = 2    ;B-channel NFAS trunk