Serial Parameters

The serial interface parameters are described in the table below.

Serial Parameters

Parameter

Description

[DisableRS232]

Enables or disables the device's RS-232 serial communication port.

■ [0] = (Default) Enables RS-232.
■ [1] = Disables RS-232.

The RS-232 serial port can be used to change the networking parameters and view error/notification messages. To establish serial communication with the device, see Establishing a CLI Session.

Note: For the parameter to take effect, a device restart is required.

[SerialBaudRate]

Defines the serial communication baud rate.

The valid values include the following: 1200, 2400, 9600, 14400, 19200, 38400, 57600, or 115200 (default).

Note: For the parameter to take effect, a device restart is required.

[SerialData]

Defines the serial communication data bit.

■ [7] = 7-bit
■ [8] = (Default) 8-bit

Note: For the parameter to take effect, a device restart is required.

[SerialParity]

Defines the serial communication polarity.

■ [0] = (Default) None
■ [1] = Odd
■ [2] = Even

Note: For the parameter to take effect, a device restart is required.

[SerialStop]

Defines the serial communication stop bit.

■ [1] = (Default) 1-bit (default)
■ [2] = 2-bit

Note: For the parameter to take effect, a device restart is required.

[SerialFlowControl]

Defines the serial communication flow control.

■ [0] = (Default) None
■ [1] = Hardware

Note: For the parameter to take effect, a device restart is required.

configure troubleshoot > startup-n-recovery > startup-dark-mode

[EnableDarkenMode]

Enables serial darkening, which hides the bootup log messages from being displayed in the CLI console during a device reset (boot up). However, if the device fails to load, serial darkening is disabled in the next bootup attempt.

■ [0]
■ [1] (Default)