Configuring Interval for QoE Report Collection and Generation
By default, the device generates QoE reports based on 30-second collection intervals of voice metrics obtained from RTCP / RTCP-XR packets. However, as packets are typically sent and received every 5 seconds, the QoE report reflects an average of these multiple packet sampling intervals (i.e., typically 6 collection intervals). Therefore, you might want to shorten the device's QoE collection and generation interval to get the following benefits:
|
■
|
More reports generated for the call. |
|
■
|
Faster initial reports - first report is available soon after the call starts, providing valuable insights even for short calls. |
|
■
|
Capturing subtle changes in call quality throughout the call. |
To configure the QoE collection and generation interval, see the [QoEMediaStatisticTimer] ini file parameter.