acVMMaintenanceAlarm
This alarm is applicable only to Mediant VE /CE SBCs deployed on Azure or Google Cloud Platform.
acVMMaintenanceAlarm
Alarm |
acVMMaintenanceAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.157 |
||
Description |
The alarm is sent when the device receives a response (over REST API) from the cloud platform's metadata service of a scheduled maintenance event for the virtual machine on which the device is installed. The alarm indicates the type of event and the scheduled time of the event. Note: This feature is configured by the [MaintenanceEventsMonitoringEnable] and [MaintenanceEventsTreatmentEnable] parameters. For more information on the device's monitoring and handling of virtual machine maintenance events by the cloud platform, refer to the device's User's Manual. |
||
Default Severity |
Warning |
||
Source Varbind Text |
Board#1 |
||
Event Type |
Other |
||
Probable Cause |
Other |
||
Severity |
Condition |
Text |
Corrective Action |
Warning |
A maintenance event is scheduled for the virtual machine on which the device is installed. |
"VM maintenance event was detected. Event type = “<event>”, Scheduled time = <UTC time>, Event id = <ID>." |
- |
Cleared |
The maintenance event has completed. |
- |
- |