Establishing a CLI Session

You can access the device's CLI using any of the following methods:

■ RS-232: The device's CLI can be accessed through its RS-232 serial port, by connecting a VT100 terminal to it or using a terminal emulation program (e.g., HyperTerminal) with a PC. For connecting to the CLI through RS-232, see CLI.
■ Secure SHell (SSH): The device's CLI can be accessed through its Ethernet interface by the SSH protocol using SSH client software. A popular and freeware SSH client software is PuTTY, which can be downloaded from https://www.putty.org.
■ Telnet: The device's CLI can be accessed through its Ethernet interface by the Telnet protocol using Telnet client software.

The following procedure describes how to access the CLI through Telnet/SSH.

● The CLI login credentials are the same as all the device's other management interfaces (such as Web interface). The default username and password is "Admin" and "Admin" (case-sensitive), respectively. To configure login credentials and management user accounts, see Configuring Management User Accounts.
● After three consecutive failed login attempts because of incorrect credentials, the device ends the CLI session and you will need to re-establish it.
➢ To establish a CLI session through Telnet or SSH:
1. Connect the device to the network.
2. Establish a Telnet or SSH session using the device's OAMP IP address.
3. Log in to the session using the username and password assigned to the Admin user of the Web interface:
a. At the Username prompt, type the username, and then press Enter:
Username: Admin
b. At the Password prompt, type the password, and then press Enter:
Password: Admin
c. At the prompt, type the following, and then press Enter:
> enable
d. At the prompt, type the password again, and then press Enter:
Password: Admin